The Model 880 Frequency Response Analyzer (FRA) Electrochemical Impedance Spectroscopy and High Frequency Resistance Measurements is available for integration with the Scribner’s electronic load used in the 840 / 850 / 890 series of fuel cell test products. The 880 FRA meets or exceeds the performance and accuracy requirements needed for all fuel cell testing applications.

The 880 FRA and FuelCell® software facilitates continuous, single-frequency High Frequency Resistance (HFR) and full-frequency range Electrochemical Impedance Spectroscopy (EIS) analysis of an operating fuel cell. HFR can be performed concurrently with current interrupt (IR drop) measurement for orthogonal determination of the cell internal or ohmic resistance.

The 880 FRA can also be integrated with the Model 910 Multi-Channel Microelectrode Analyzer (MMA) for impedance spectroscopy of electrode and sensor arrays.

decriptionKey features

• Generator Frequency Range 1 mHz to10 kHz
• Frequency Error < 0.01%
• Amplitude Range ±10 mV to ±3.000 V
• Amplitude Resolution 1 part in 32,768
• Amplitude Error < 1% ± 1 digit
• Distortion < 0.02%
• Analyzer Type Quadrature method (digital correlation)
• Input Ranges(RMS) 30 mV, 300 mV, 3 V RMS
• Full Scale Peak Input 50 mV, 500 mV, 5 V
• Cross Channel Isolation > 100 dB
• Measurement Time, minimum Longer of 1 cycle or 10 ms
• Measurement Cycles Dependent on integration setting
• Error Limits 0.5% Magnitude error (1 mHz to 10 kHz) / 0.5 ° Phase error (1 mHz to 10 kHz)
decriptionTechnical Specifications

Electronic Load
Maximum Load Current 5, 15, 25, 50 or 125 A (configuration dependent)
Maximum Load Power 125 W (15, 25, 50 A units), 100 W (5 A unit), 500 W (125 A unit)
Minimum Load Resistance <2 mW for 125/50 A, <3 mW for 25 A unit
Current Resolution 1 mA on 5 and 15 A units
10 mA on 25, 50 and 125 A units
Current Accuracy ±0.3% of full scale current rating
Voltage Measurement and Data Acquisition
Maximum Whole Cell Voltage 20 V
Maximum Reference Electrode Voltage 9.999 V
Sense Lead Input Resistance >35 kW
Voltage Resolution 1 mV
Voltage Accuracy ±3 mV ±0.3% of reading
Voltage and Current Data Update Rate 100 Hz
Fuel Interface
Outputs for anode, cathode MFC Two, Analog (0-5 V)
Alarm Inputs Six: Three for gas pressures, three auxiliary
Fuel Solenoid Control One 5 V output (external relay needed)
Temperature Controllers
Quantity One or three (see options)
Type On/off 5 V output (external SSR required)
Set and Report Accuracy ±0.25% of span, ±1 least significant digit
Sensor Type Thermocouple, Type T, K, or S (specify)
Environment
Operating Temperature 0 to 40 °C ambient
Power Source 100-240 VAC, 50/60 Hz (auto select)
Size 3U standard rack mount, 19″W x 5.25″H x 21″D
Configuration Options at Manufacture
Reformate outputs Up to 5 additional channels available
Current Range Select 5, 15, 25, 50 or 125 A
Temperature Control Channels Standard configuration of 3 controllers
Hardware Notes
Thermocouple connector type Miniature connectors, T, K or S type
Enclosure Aluminum chassis, polymer panel overlay